Serious specs for serious users
-
PROVEN RUGGED IN THE REAL WORLD
Military personnel depend on their mobile computing systems to execute mission plans, perform daily tasks and in some cases save lives. Designed for and with frontline personnel, the iX104C5M stands up to real world conditions such as 4' operating drops to concrete, driving rain, blowing sand and dust, constant vibration, temperature extremes and more. Independent MIL-STD-810G, 461F, IP and Hazardous Location testing in combination with rugged design innovations instill confidence the iX104C5M will protect critical data and deliver in the most challenging tactical conditions.
Powered by the newest Intel® Core™ i7 processor, the iX104C5M offers the most advanced performance platform in its class, enabling government and military organisations to confidently deploy multi-mission applications to the field thereby helping to enhance situational response times and improve efficiencies.
The iX104C5M delivers maximum input flexibility and usability with an optically-engineered rugged sunlight-viewable display with AllVue™ Xtreme technology and innovative auto-switching dual-mode digitizer that supports both gloved-touch and active pen inputs on the fly. Single or dual solid state drives (with integrated heater) and RAID configuration options delivery Industry-Leading realiability, performance and data integrity.
-
TOTAL CONTROL OF OWNERSHIP
The iX104C45M incorporates advanced technologies from industry leaders and was designed to provide long, stable lifecycles. Its proven track record of high reliability and low failure rates means greater system uptime for military epronsnnel.
Technical Specifications
-
Fully Rugged
-
Multi-layered desert tan magnesium chassis
-
MIL-STD-810G, MIL-STD-461, IP67
-
Hazardous Location Certified
-
Piston Sealing, Rugged SSD Cartridge
-
Processor
-
Intel® Core™ i7, 620 UE processor with Turbo Boost Technology (up to 2.13Ghz)
-
(1.06 GHz / 800-1067MHz FSB / 4 MB L2 Smart Cache)
-
Chipset
-
Graphics
-
Mobile Intel® High Definition (HD) Graphics
-
Display
-
10.4" XGA (1024x768) rugged LED backlit display
-
Dual-Mode AllVue™ Xtreme technology –industry’s best outdoor sunlight-readable display
-
Contrast Ratio = 600:1 (typical)
-
Automatic Light Sensor (ALS), NVIS compatible
-
Dual Mode auto-sensing Touch & Pen input
-
Memory
-
Standard 2GB Dual-Channel DDR3 Memory (up to 1333Mhz)
-
Expandable to 8GB (with Windows® 7, 64-bit OS)
-
User-accessible bay
-
Operating Systems
-
Genuine Microsoft® Windows® 7, 32-bit
-
Genuine Microsoft® Windows® 7, 64-bit
-
Software
-
xConnect Mobile Broadband Connection Manager with NDIS
-
xCapture photo and video for landscape & portrait capture
-
Battery
-
Standard 10-cell high-capacity (68.5Whr) Lithium removable battery, up to 6.5hrs battery life
-
Warm Swap Capabilities
-
Power Supply
-
Auto sensing 100-240V, 50-60Hz supplying 19VDC
-
Storage
-
User-accessible, tool-less removable drive cartridge
-
Dual drive capabilities in protective drive cartridge
-
RAID 0,1 capable with dual SSD drives (JBOD support)
-
Standard high performance 80GB mSATA drive with integrated heater
-
Integrated Communications
-
LAN: 10/100/1000 Gigabit Ethernet (RJ-45)
-
Integrated Wireless LAN: Intel® Centrino® Advanced- N6200 (802.11 a/b/g/n)
-
Keypad: Programmable Radio Toggle (Wireless On/Off)
-
GPS: Dedicated GPS & Antenna receiver modules (2 meter and sub-meter options)
-
Security
-
Biometrics/Fingerprint Reader (navigation capabilities)
-
TPM 1.2
-
Intel® Anti-Theft
-
Computrace® Application Agent option
-
Kensington® lock slot
-
Collaboration
-
Stereo Speakers with high definition audio
-
Noise Canceling Microphone
-
Integrated 3 Megapixel digital camera (rear facing) for still and video imaging, bar code capable
-
Ports
-
AC/DC power
-
Docking connector
-
USB 2.0 (x2)
-
RJ-45
-
Headphone/speaker out and microphone
-
VGA (optional 9-pin Serial port (RS232/RS422/RS485))
-
MicroSD and SIM socket (tool-less removable door)
-
Top & Side (RS232/RS422/RS485 signal ready) Pin & Pad expansion ports
-
Input & Status Indicators
-
Dual-Mode - Touch and Active Pen, Input with auto-sensing and switching technology
-
Programmable Application Buttons - primary and secondary functions
-
Power on/Resume button, Reset Button, CTL/ALT/DEL, Screen orientation
-
X + Y navigation (mouse-like) via biometric scanner
-
Status Indicators Power, Charge/DC-in, SSD LEDs
-
Dimensions
-
11.2"(284.4mm) x 8.25"(209.5mm) x 1.6"(40.7mm) (W x H x D)
-
Weight
-
Peripherals and Docking
-
Custom Military Vehicle Docking Systems (Dock, Power, Charge, I/O Pass-thru, Locking Connectors, Power Management)
-
Warranty
-
Standard three (3) year limited warranty
-
Environmental Specifications
-
Independently-tested to MIL-STD-810G
-
Operating Temperature: -4°F to 140°F (-20°C to 60°C)
-
Operating Temperature (with mDock or powered): -49°F to 140°F (-45°C to 60°C)
-
Storage Temperature: -60°F to 160°F (-51°C to 71°C)
-
Humidity: 3% - 95% non-condensing
-
Thermal Shock: -60°F to 160°F (-51°C to 71°C)
-
Blowing Rain: 4.0"/hr (101.6mm/hr) blowing rain, 40mph wind source, 30 minutes
-
Blowing Sand and Dust: 30mph wind source, 30 minutes
-
Vibration: Minimum Integrity, Vehicle Vibration, US Highway Truck Vibration
-
Salt Fog: 5% saline, 48 hr exposure
-
Altitude: 50,000ft (12,192m) operating
-
Other Tests: Bench Shock, Functional and Crash Shock, Contamination by Fluids, Fungus and Solar Radiation
-
Beyond MIL-STD-810G
-
Transit Drop - Operating 4' (1.22m): drop direct to concrete while system is operating, 26 drops
-
Transit Drop - Operating 7' ( 2.13m): drop direct to plywood over concrete while system is operating, 26 drop
-
IEC Ingress Testing
-
IEC (60529) Ingress Tested to an IP67 standard (10-cell Battery). Submersion resistant, dust tight
-
Emissions, Immunity & Safety
-
Emissions MIL-STD 461F, FCC Part 15, CE Mark EN55022 (CISPR22) Class B, E-Mark (xDock)
-
Immunity EN55024
-
Safety UL and EN60950-1 2nd Ed., ATEX Zone 2/Category 3 Compliant, UL 1604 (ISA Std 12.12-CSA Std C 22.1) Class I/Division II (Z:A-D) certified
-
Other
-
ROHS, Energy Star 5.0 Compliant
Rugged Specifications
MIL-STD-810G Testing
-
Transit Drop-Operating
-
4'(1.22 m); drop direct to concrete, 26 total drops: one drop to each face, edge and corner. Unit is operating and remains operational.
-
Exceeds MIL-STD-810G, Method 516.6, Proc IV
-
7' (2.13 m); drop direct to plywood over concrete, 26 total drops: one drop to each face, edge and corner. Unit is operating and remains operational.
-
Exceeds MIL-STD-810G, Method 516.6, Proc IV
-
Minimum Integrity Vibration
-
Minimum Integrity testing. Unit is not operating.
-
MIL-STD-810G, Method 514.6, Procedure I: Figure 514.6 E-1, Category 24
-
Vehicle Vibration
-
Vehicle vibration testing. Unit is operating.
-
MIL-STD-810G, US Highway Truck, Method 514.6, Procedure I: Figure 514.6 C-1 Category 4. Tablet with mDock and Vehicle Kit
-
Temperature Extremes (Operating/Non-Operating)
-
Operating: -4°F to 140°F (-20°C to 60°C): Unit is operating. Cold boot within 15 min (power source)
-
Operating: (with SSD/Heater & Military mDock or powered): -49°F to 140°F (-45°C to 60°C)
-
Non-Operating/Storage: -60°F to 160°F (-51°C to 71°C). Unit is not operating
-
MIL-STD-810G, Methods 501.5, 502.5, Procedures I & II
-
Thermal Shock
-
-60°F to 160°F (-51°C to 71°C).
-
MIL-STD-810G Method 503.5, Procedure II, cyclic: Unit is not operating
-
Blowing Rain
-
4.0 in/hr (101.6 mm/hr) of blowing rain with a 40 mph wind source for 30 minutes on each surface. Unit is operating.
-
MIL-STD-810G, Method 506.5, Procedure I
-
Blowing Sand & Dust
-
Blowing sand and dust at 30mph for 30 minutes. Unit is operating.
-
MIL-STD-810G, Method 510.5, Procedures I (Blowing Dust) & II (Blowing Sand)
-
Humidity
-
3%-95% - non-condensing humidity. Five 48-hour cycles. Unit is operating
-
MIL-STD-810G, Method 507.5, Procedure II
-
Salt Fog Spray
-
5% saline exposure for 2 Cycles x 48 hrs (24hrs wet/24hrs dry). Unit is not operating
-
MIL-STD-810G, Method 509.5, Procedure I
-
Bench Shock (M5)
-
4" (101.6mm) drop onto wooden bench. Four drops on each face. Unit is not operating
-
MIL-STD-810G, Method 516.6, Procedure VI
-
Functional Shock
-
40g (peak), 11 ms, saw-tooth, 3 axis x 6 shocks = 18 shocks. Unit is not operating. 20g (peak) operating
-
MIL-STD-810G, Method 516.6, Procedure I
-
Crash Shock
-
75g (peak), 11ms, saw tooth, 2+/- shocks x 3 axis = 6 shocks. Unit is not operating.
-
MIL-STD-810G, Method 516.6, Procedure V
-
Altitude
-
Chamber at 50,000ft for 1 hour. Unit is operating
-
MIL-STD-810G, Method 500.5, Procedure II
-
Contamination by Fluids
-
Detergents, brake fluid, aromatic hydrocarbons. Unit is not operating
-
MIL-STD-810G, Method 504.1
-
Fungus
-
28 days; US Fungus Types. No growth. Unit is not operating.
-
MIL-STD-810G, Method 508.6, Procedure I
-
Solar Radiation
-
Steady State A1. 1120 W/m2 (355 Btu/ft2/hr) UVB @ 500C, 7x24hr cycles. Unit is not operating
-
MIL-STD-810G, Method 505.5-2, Procedure II
Ingress Testing
-
IEC (IP) Ingress Protection Testing
-
IP 67 (10-Cell Battery) Dust tight, no ingress of dust. Protection against effects of immersion in water to 3.28' (1m).
-
IEC 60529 IP 67 for dust and water
Hazardous Environments Testing and Certification
-
UL1604/ISA Std 12.12 (CSA 22.1)
-
Operation in Hazardous Environments; (Class 1, Division 2, Zones A/B/C/D)
-
ATEX
-
Operation in Hazardous Environments; ATEX compliant
DC Power, Electrostatic & Environmental
-
DC & Electrostatic
-
12-33 VDC for M5 Tablet and Military Vehicle Docking Station (mDock). Per MIL-STD-1275D. 15kV air, 8 kV contact electrostatic discharge per SAE J1113/13, Class A M5 Tablet and Military mDock
-
461F Emissions
-
MIL-STD 461F; CS-101, 114, 115 and 116; CE-102; RE-102; RS-103, 105, and 2169-B
Additional Compliance
-
Automotive
-
Compliance with latest version of EU Directive 72/245/EEC including amendments and corrigenda (2004/104/EC) Automotive E Mark (mDock)
Download Brochures